BJHQM - 4083 AEROSOL MOTOR DEGREASER

  • MSDS: BJHQM
  • Manufacturer: CALGON VESTAL LABORATORIES
  • Product Name: 4083 AEROSOL MOTOR DEGREASER
  • National Stock Number: 6850-00F013470
Product Identification

Product ID:4083 AEROSOL MOTOR DEGREASER
MSDS Date:12/12/1988
FSC:6850
NIIN:00F013470
MSDS Number: BJHQM

Responsible Party
CALGON VESTAL LABORATORIES
5035 MANCHESTER AVENUE
ST. LOUIS, MO 63110

Emergency Phone: (314) 535-1810

Info Phone: (314) 862-2000

Preparer: R.C. JENTE

Cage: 21667

Contractor
CONVATEC, BRISTOL-MEYERS SQUIBB CO
147 ST. LOUIS, MO 63166-1096 US

Telephone: 314-535-1810 (DAY)

Cage: 21667

Ingredients

PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA III)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 50%

OSHA PEL 100 PPM

ACGIH TLV: 25PPM/100,A3 STEL;94

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 50%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: <5%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYES: IRRITATION. INHALATION:
ANESTHETIC, IRRITATION TO THE RESPIRATORY SYSTEM, LIGHT-HEADEDNESS,
STAGGERING GAIT, GIDDINESS, & POSSIBLE NAUSEA. INGESTION: HARMFUL &
FATAL.
Explanation of Carcinogenicity:PERCHLOROETHYLENE & METHYLENE CHLORIDE
IS CONSIDERED TO BE AN A2 CARCINOGEN.
Effects of Overexposure:INHALATION: REPEATED/PROLONGED EXPOSURE TO
SOLVENTS MAY CAUSE PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE, KIDNEY
& LIVER DAMAGE. SKIN/EYES: IRRITATION. INGESTION: HARMFUL & FATAL.

First Aid

First Aid:INHALATION: REMOVE PATIENT TO FRESH AIR. EYES: FLUSH W/WATER
FOR AT LEAST 15 MINUTES. SKIN: WASH W/SOAP & WATER. INGESTION: CALL
PHYSICIAN. DON'T INDUCE VOMITING.

Fire Fighting

Flash Point:NONE
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE. WATER MAY BE USED TO
KEEP FIRE EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:KEEP AT ROOM TEMPERATURES AS EXPOSURE TO
DIRECT SUNLIGHT OR OTHER HEAT MAY CAUSE BURSTING. NON-FLAMMABLE.

Accidental Release

Spill Release Procedures:VENTILATE AREA, ESPECIALLY LOW PLACES WHERE
VAPORS WILL COLLECT. REMOVE W/INERT ABSORBENT.

Handling

Handling and Storage Precautions:DON'T STORE >120F. KEEP AT ROOM
TEMPERATURE AS EXPOSURE TO DIRECT SUNLIGHT OR HEAT MAY CAUSE
BURSTING.
Other Precautions:KEEP AWAY FROM CHILDREN. DON'T PUNCTURE OR
INCINERATE. DON'T SPRAY NEAR FIRE OR OPEN FLAME. AVOID BREATHING OF
VAPOR OR SPRAY MIST.

Exposure Controls

Ventilation:LOCAL EXHAUST: RECOMMENDED
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GLASSES W/SIDESHIELDS
Supplemental Safety and Health
PERCHLOROETHYLENE HAS CAUSED LIVER & KIDNEY TOXIC EFFECTS IN
CHRONICALLY OVEREXPOSED EXPERIMENTAL ANIMALS.

Chemical Properties

Boiling Pt:B.P. Text:<0F
Vapor Density:>1
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:PROPELLANT W/TYPICAL ODOR
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:DIRECT SUNLIGHT, HEAT, TEMP >120F, OPEN
FLAME
Hazardous Decomposition Products:TOXIC FUMES OF CHLORIDES & FLUORIDES,
HYDROGEN CHLORIDE, & PHOSGENE GAS

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, &
FEDERAL REGULATIONS REGARDING POLLUTION. DON'T INCINERATE OR
PUNCTURE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.